The new Motor Modules partly extend the previous spectrum or the functionality. In this case,
there are special conditions of use.
Table 7-10
Motor Module
Single Motor Module
18 A C type
Double Motor Mod‐
ule 18 A D type
Single Motor Module
30 A D type
Single Motor Module
24 A C type
Single Motor Module
24 A D type
Single Motor Module
45 A C type
Single Motor Module
60 A C type
The latest information on the SINAMICS components that can be used is available at:
FAQ (https://support.industry.siemens.com/cs/de/en/view/11886029)
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
7.5 Additional information on configuring the SINAMICS Integrated
Conditions of use for Motor Modules C/D type
Article number
6SL3120-1TE21-8
AC0
6SL3120-2TE21-8
AD0
6SL3120-1TE23-0
AD0
6SL3120-1TE22-4
AC0
6SL3120-1TE22-4
AD0
6SL3120-1TE24-5
AC0
6SL3120-1TE26-0
AC0
Conditions of use
These Motor Modules extend the previous spectrum and
can only be used with:
● SIMOTION SCOUT V4.5
With SIMOTION Runtime/firmware: V4.4 as of
HF11 (SINAMICS Integrated V4.7 as of HF17) or
With SIMOTION Runtime/firmware V4.5
(SINAMICS Integrated V4.8) and installed SSP
SINAMICS V4.8 HF1
● SIMOTION SCOUT TIA V4.5
With SIMOTION Runtime/firmware: V4.4 as of
HF11 (SINAMICS Integrated V4.7 as of HF17)
NOT with SIMOTION Runtime/firmware V4.5
(SINAMICS Integrated V4.8) -> SSPs cannot be
installed in the TIA Portal and therefore cannot be
used with SCOUT TIA)
● SIMOTION SCOUT / SCOUT TIA as of V5.1
With SIMOTION Runtime/firmware: As of V4.4
HF11 (SINAMICS Integrated as of V4.7 HF17)
SCOUT V4.4 HFx
Does not contain an integrated STARTER V4.4 with Serv‐
ice Pack 1, which is required for the configuration of these
three Motor Modules.
For details, see also:
Link
(https://support.industry.siemens.com/cs/ww/en/
view/109480497)
Engineering: SCOUT / SCOUT TIA as of V5.1
and SIMOTION Runtime/firmware as of SIMOTION V4.5
(SINAMICS Integrated as of V4.8)
The 24 A Motor Modules require a new firmware in each
case.
The 45 A and 60 A Motor Modules require a current firm‐
ware if the maximum current of 90 A or 120 A is to be
utilized.
For details, see also:
Link
(https://support.industry.siemens.com/cs/ww/en/
view/109751266)