Connecting

4.9 Connecting Ethernet

4.9
Connecting Ethernet
4.9.1

Wiring Ethernet

Procedure
To the 8-pin RJ45 sockets
● X127 P1
● X130 P1
● X120 P1 (only for D4x5-2 DP)
you can connect Industrial Ethernet.
The interfaces support a transmission rate of 10/100/1000 Mbit/s. Suitable Ethernet cables
and connectors must be used for the Ethernet connection.
Figure 4-18
Note
As of V4.3, the three Ethernet interfaces support the PROFINET basic services - they therefore
have the designation PN/IE-NET, PN/IE-OP or PN/IE.
These PROFINET basic services (e.g. DCP, LLDP, SNMP) provide uniform functions for the
address assignment and diagnostics, but do not provide PROFINET IO communication for the
connection of drives, I/O modules, etc.
88
Connecting Industrial Ethernet
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
SIMOTION D4x5-2