See also
If you configure the telegrams for the infeed and drive manually, you can find detailed
information on the respective telegram types in the following:
Motion Control, TO Axis Electrical/Hydraulic , External Encoder Function Manual
SINAMICS S120 Function Manual
7.2.4

Downloading a project into the target system

Requirement
You have configured the hardware. You now need to download the hardware configuration
and the entire SIMOTION project to the target system.
If you have not yet configured your SIMOTION project (i.e. created ST programs, assigned
execution levels, etc.), complete this step first.
Note
You can only perform a project download in the STOP operating mode and for all target devices
with which you are ONLINE. You cannot download to drives that cannot be configured in
SCOUT, e.g MASTERDRIVES. The project data is loaded to all the devices connected
ONLINE and their subordinate drive units (provided these are selected in the Target Device
Selection dialog box). This can only be done in the STOP operating mode.
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Displaying the topology
7.2 Performing the configuration for the D4x5-2 offline
Commissioning (software)
197