Siemens SIMOTION D4x5-2 Commissioning And Hardware Installation Manual page 391

Hide thumbs Also See for SIMOTION D4x5-2:
Table of Contents

Advertisement

Name
D4x5-2:
PN
CBE30-2:
FAULT
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Color
State
Meaning
red
Off
as an IO controller:
● PROFINET interface is operating without error; the data exchange to
as an I‑Device:
● PROFINET interface is running without error, there is at least one
On
PROFINET interface bus fault
● No physical connection to a subnet/switch
● Incorrect transmission rate
● Full duplex transmission is not activated
● More than one IP address/NameOfStation in the network
Flashing
as an IO controller:
(2 Hz)
● Failure of a connected IO device
● At least one of the assigned IO devices cannot be addressed.
● Incorrect or no configuration
as an I-device:
The LED flashes until at least one controller has correctly established com‐
munication with this I‑Device.
Possible causes:
● Incorrect IP address
● Incorrect configuration / parameterization
● IO controller not connected / switched off, although an Ethernet
● IN Shared I‑Device operation: all configures IO controllers are not
● Incorrect or missing device name.
● The response monitoring interval has elapsed
● The CPU is an I‑Device and communication with the higher-level
flashing
CBE30‑2 power-up stopped,
(0.5 Hz)
possible reason: CBE30-2 is plugged into wrong Control Unit.
(CBE30-2 is only supported by SIMOTION D4x5-2 DP/PN, not by SIMO‐
TION D4x5-2 DP)
all configured IO devices is running
communication link with the I‑Device
connection has been established.
connected/switched off, but the Ethernet connection is up (link
established to the neighboring device)
controller fails
Diagnostics
9.1 Diagnostics via LED displays
391