Commissioning (software)
7.8 Activating the infeed (line module)
The following table shows which interconnection options are available, depending on the
topology.
Table 7-11
Interconnection options for the ready signal of an infeed
Infeed is controlled by ...
SINAMICS Integrated of D4x5‑2
CX32-2
CU320-2
①
Use of the CU-Link (DRIVE-CLiQ data transfer channel); by factory setting, the ready signal of an infeed on the SINAMICS
Integrated is automatically communicated to the connected Controller Extensions and only has to be interconnecgted to the
drives there.
For details, see Section Interconnecting the infeed "Operation" signal on the CX32-2 (Page 221).
②
For the interconnection, the CU‑Link (DRIVE-CLiQ data transfer channel) can be used. For this purpose, it is necessary
to configure the CU‑Link according to the requirements.
For details, see Section CU-Link (data transfer via DRIVE-CLiQ) (Page 241).
③
Wiring via terminals is recommended.
An interconnection of the Ready for operation signal via PROFIBUS/PROFINET is not recommended because of the delay
times (communication, evaluation in controller, etc.) or a possible CPU stop (no execution of the user program).
270
Ready signal of the infeed to be inter‐
connected to ...
CX32-2
CU320-2
SINAMICS Integrated of D4x5‑2
CX32-2
CU320-2
SINAMICS Integrated of D4x5-2
CX32-2
CU320-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
Recommended interconnection option
for the ready signal of the infeed
①
Default CU-Link interconnection
③
Wiring via terminals
②
Individual CU-Link interconnection
③
Wiring via terminals
③
Wiring via terminals
SIMOTION D4x5-2