Service and maintenance
8.3 Adapting a project (Upgrading the project / Replacing the SIMOTION controller)
8.3.10

Save project, compile and check consistency

Procedure
1. Execute "Save and recompile all" ("Project" > "Save and recompile all" menu).
2. Then perform a consistency check ("Project" > "Check consistency" menu).
3. If error messages occur, correct these and repeat the operation.
Note
Note the difference between
● "Save and recompile all" and
● "Save and compile changes"
Save and recompile all
All sources of the entire project are recompiled with this command.
The command is suitable if you are quite sure that all the old data from older SCOUT versions
should be removed and replaced with new compilation results.
Use this command if you specifically want to convert a project from an earlier SCOUT version
to a newer version. In this way, you take over all error corrections and optimizations.
Save and compile changes
On this command, the whole project is searched for changes. Therefore only the changes are
compiled. Use this command for day-to-day operations within a SCOUT version.
358
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
SIMOTION D4x5-2