5 Adjustments
5.9.1 Feedforward Reference
5.9
Compatible Adjustment Function
The DC Power Input Σ-V series SERVOPACKs have adjustment functions as explained in sections 5.1 to 5.8
to make machine adjustments.
This section explains compatible functions provided by earlier models, such as the Σ-III Series SERVOPACK.
5.9.1
Feedforward Reference
This function applies feedforward compensation to position control and shortens positioning time.
Position
reference
Pn109
Pn10A
Note: Too high value may cause the machine to vibrate. For ordinary machines, set 80% or less in this parameter.
5-84
Pn109
Feedforward Gain
Differential
+
Position loop gain (Kp)
-
Feedback pulse
Feedforward Gain
Setting Range
0 to 100
Feedforward Filter Time Constant
Setting Range
0 to 6400
Pn10A
Feedforward Filter
Time Constant
+ +
Setting Unit
Factory Setting
1%
Setting Unit
Factory Setting
0.01 ms
MECHA
Position
When Enabled
0
Immediately
Position
When Enabled
0
Immediately
Classification
Tuning
Classification
Tuning