4 Operation
4.1.1 Setting Switches SW1 and SW2
(2) Setting the Station Address
The following table lists the possible settings of the DIP switches (SW1, SW2) that can be combined to form a
station address.
The factory setting for the station address is 41H (Bit 3 of SW2 = OFF, Bit 1 of SW1 = ON, Bit 2 of SW1 =
OFF, Bit 3 of SW1 = OFF, Bit 4 of SW1 = OFF).
Bit 3 of SW2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4-4
Bit 1 of SW1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
• To enable the change in the setting, restart the SERVOPACK.
Setting
Bit 2 of SW1
Bit 3 of SW1
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Station Address
Bit 4 of SW1
OFF
Disabled
OFF
41H
OFF
42H
OFF
43H
OFF
44H
OFF
45H
OFF
46H
OFF
47H
ON
48H
ON
49H
ON
4AH
ON
4BH
ON
4CH
ON
4DH
ON
4EH
ON
4FH
OFF
50H
OFF
51H
OFF
52H
OFF
53H
OFF
54H
OFF
55H
OFF
56H
OFF
57H
ON
58H
ON
59H
ON
5AH
ON
5BH
ON
5CH
ON
5DH
ON
5EH
ON
5FH