YASKAWA E-V Series User Manual page 243

Ac, dc power input, rotational motor, mechatrolink-ii communications reference, servomotor, servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

6 Utility Functions (Fn
5.
Click Measurement complete.
6.
If setting the parameters to the values shown in the measurement results, click Result Writing.
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn456
6-44
)
Torque Related Function Switch
1st Notch Filter Frequency
1st Notch Filter Q Value
2nd Notch Filter Frequency
2nd Notch Filter Q Value
Sweep Torque Reference Amplitude
Name
MECHA
Mid-execution
Automatic
changes
changes
Yes
Yes
No
Yes
No
No
No
Yes
No
No
No
No

Advertisement