6 Utility Functions (Fn
3.
Click Execute.
The new settings for the vibration detection level will be shown in the boxes in lower section of the box.
The new settings will be saved in the SERVOPACK.
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn311
Pn312
6-34
)
Vibration Detection Sensitivity
Vibration Detection Level
Name
MECHA
Mid-execution
Automatic
changes
changes
Yes
No
No
Yes