YASKAWA E-V Series User Manual page 220

Ac, dc power input, rotational motor, mechatrolink-ii communications reference, servomotor, servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

(3) Operating Procedure
Use the following procedure.
1.
Connect the measurement instrument.
For details, refer to 5.1.3 (1) Connecting the Measurement Instrument.
2.
In the SigmaWin+ main window, click Setup - Adjust Offset - Adjust the Analog Monitor
Output. The Adjust the Analog Monitor Output box will appear. Click Zero Adjustment tab.
In the Channel box, either CH1 or CH2 can be selected.
3.
To adjust the offset, click +1 (increase) or -1 (decrease) button while viewing the analog monitor
to check the output level. Keep the output as close to zero as possible.
6.8 Offset Adjustment of Analog Monitor Output (Fn00C)
MECHA
6
6-21