Troubleshooting Of Warnings - YASKAWA E-V Series User Manual

Ac, dc power input, rotational motor, mechatrolink-ii communications reference, servomotor, servopack
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

8 Troubleshooting

8.2.2 Troubleshooting of Warnings

8.2.2

Troubleshooting of Warnings

Refer to the following table to identity the cause of a warning and the action to be taken. Contact your
Yaskawa representative if the problem cannot be solved by the described corrective action.
Warning
Number:
Warning Name
(Warning
Description)
A.900:
Position Error
Overflow
A.901:
Position Error
Overflow Alarm
at Servo ON
A.910:
Overload
(Warning before
alarm A.710 or
A.720 occurs)
8-16
Cause
The servomotor U, V,
Check the servomotor main circuit
and W wirings is faulty.
cable connection.
The SERVOPACK gain
Check the SERVOPACK gain.
is too low.
The acceleration of the
Reduce the reference acceleration, and
position reference is too
operate the SERVOPACK.
high.
Setting of the excessive
position error alarm
Check the alarm level (Pn520) to see
level (Pn520) is low
if it is set to an appropriate value.
against the operating
condition.
A SERVOPACK fault
occurred.
When the servomotor
power is ON, the posi-
tion error exceeded the
parameter setting
(Pn526×Pn528/100).
Incorrect wiring or con-
tact fault of servomotor
Check the wiring.
and encoder.
Operation beyond the
Check the motor overload characteris-
overload protection
tics and executed run command.
characteristics.
Excessive load was
applied during opera-
tion because the servo-
Check the executed operation refer-
motor was not driven
ence and motor speed.
due to mechanical prob-
lems.
A SERVOPACK fault
occurred.
Investigative Actions
Corrective Actions
Confirm that there is no contact fault
in the motor wiring or encoder wiring.
Increase the servo gain by using the
function such as advanced autotuning.
Reduce the reference acceleration of
the position reference using a
MECHATROLINK command, or
smooth the acceleration of the position
reference by selecting the position ref-
erence filter (ACCFIL) using a
MECHATROLINK command.
Set the Pn520 to proper value.
Restart the SERVOPACK. If the alarm
still occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Set an appropriate value for the exces-
sive position error warning level at
servo ON (Pn528).
Confirm that the servomotor and
encoder are correctly wired.
Reconsider the load conditions and
operating conditions. Or, increase the
motor capacity.
Remove the mechanical problems.
The SERVOPACK may be faulty.
Replace the SERVOPACK.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-v sgmmvE-v sgdv

Table of Contents