Interface Features
Table 205 Interface specifications
Item
Protocol supported
Hardware algorithm
Panel and LEDs
Figure 171 FIC-HNDE panel
Table 206 LED description
LED
STATUS
ACTIVE
Troubleshooting
You can learn how well the encryption module is operating by reading the LEDs on it.
For the correct LED behaviors, see
Table 207 Troubleshooting by reading the LED behaviors
Incorrect LED behaviors
STATUS LED remains off at
router startup.
ACTIVE LED remains off at
device startup.
Description
IPSec
key algorithm (DES, 3DES, AES)
Authentication algorithm (HMAC-MD5-96, HMAC-SHA-1-96)
Description
•
Steady green: Power is being supplied to the FIC-HNDE normally.
•
Off: The module is not powered, the power supply of the module has failed or a
serious hardware fault occurs.
•
Off after two-second flashing (yellow): The module has been initialized.
•
Flashing: The module operates normally and data is being transmitted or received.
•
Off: The module is operating normally but not sending or receiving data.
Table
Reason
The module or some
hardware parts on the
module are not supplied
with power properly.
The encryption processor
failed to initialize the
configurations possibly
due to a system bus
problem.
207.
Action to take
Check that the power supply of the
1.
router is correctly connected.
Check that the power is being supplied.
2.
Contact your sales agent for help: the
3.
power supply of the module may have
been damaged or anomalies have
occurred to the CPLD.
Check that the module is securely
1.
connected to the host.
Contact your sales agent for help: the
2.
host or the module may be problematic.
151
Need help?
Do you have a question about the MSR Router Comware 5 Series and is the answer not in the manual?
Questions and answers