Keysight Technologies InfiniiVision MSO-X 4022A Programmer's Manual page 390

Hide thumbs Also See for InfiniiVision MSO-X 4022A:
Table of Contents

Advertisement

18
:FUNCtion<m> Commands
Table 101 :FUNCtion<m> Commands Summary (continued)
Command
:FUNCtion<m>:CLEar
page
400)
(see
:FUNCtion<m>:DISPlay
{{0 | OFF} | {1 |
page
401)
ON}} (see
:FUNCtion<m>[:FFT]:CE
NTer <frequency> (see
page
402)
:FUNCtion<m>[:FFT]:FR
EQuency:STARt
<frequency> (see
page
403)
:FUNCtion<m>[:FFT]:FR
EQuency:STOP
<frequency> (see
page
404)
:FUNCtion<m>[:FFT]:GA
TE <gating> (see
page
405)
:FUNCtion<m>[:FFT]:PH
ASe:REFerence
<ref_point> (see
page
406)
:FUNCtion<m>[:FFT]:SP
AN <span> (see
page
407)
:FUNCtion<m>[:FFT]:VT
YPe <units> (see
page
408)
:FUNCtion<m>[:FFT]:WI
NDow <window> (see
page
409)
390
Query
n/a
:FUNCtion<m>:DISPlay?
page
401)
(see
:FUNCtion<m>[:FFT]:CE
page
402)
NTer? (see
:FUNCtion<m>[:FFT]:FR
EQuency:STARt? (see
page
403)
:FUNCtion<m>[:FFT]:FR
EQuency:STOP? (see
page
404)
:FUNCtion<m>[:FFT]:GA
page
405)
TE? (see
:FUNCtion<m>[:FFT]:PH
ASe:REFerence? (see
page
406)
:FUNCtion<m>[:FFT]:SP
page
407)
AN? (see
:FUNCtion<m>[:FFT]:VT
page
408)
YPe? (see
:FUNCtion<m>[:FFT]:WI
page
409)
NDow? (see
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
Options and Query Returns
n/a
{0 | 1}
<m> ::= 1 to (# math functions)
in NR1 format
<frequency> ::= the current
center frequency in NR3 format.
The range of legal values is from
-25 GHz to 25 GHz.
<m> ::= 1 to (# math functions)
in NR1 format
<frequency> ::= the start
frequency in NR3 format.
<m> ::= 1 to (# math functions)
in NR1 format
<frequency> ::= the stop
frequency in NR3 format.
<m> ::= 1 to (# math functions)
in NR1 format
<gating> ::= {NONE | ZOOM}
<m> ::= 1-4 in NR1 format
<ref_point> ::= {TRIGger |
DISPlay}
<m> ::= 1-4 in NR1 format
<span> ::= the current frequency
span in NR3 format.
Legal values are 1 Hz to 100 GHz.
<m> ::= 1 to (# math functions)
in NR1 format
<units> ::= {DECibel | VRMS} for
the FFT (magnitude) operation
<units> ::= {DEGRees | RADians}
for the FFTPhase operation
<m> ::= 1 to (# math functions)
in NR1 format
<window> ::= {RECTangular |
HANNing | FLATtop | BHARris}
<m> ::= 1 to (# math functions)
in NR1 format

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InfiniiVision MSO-X 4022A and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Infiniivision 4000 x seriesInfiniivision mso-x 4032aInfiniivision mso-x 4034aInfiniivision mso-x 4054aInfiniivision mso-x 4104aInfiniivision mso-x 4154a ... Show all

Table of Contents