Measure:pwidth - Keysight Technologies InfiniiVision MSO-X 4022A Programmer's Manual

Hide thumbs Also See for InfiniiVision MSO-X 4022A:
Table of Contents

Advertisement

22
:MEASure Commands

:MEASure:PWIDth

Command Syntax
:MEASure:PWIDth [<source>]
<source> ::= {<digital channels> | CHANnel<n> | FUNCtion<m> | MATH<m>
<digital channels> ::= DIGital<d> for the MSO models
<d> ::= 0 to (# digital channels - 1) in NR1 format
<n> ::= 1 to (# of analog channels) in NR1 format
<m> ::= 1 to (# math functions) in NR1 format
<r> ::= 1 to (# ref waveforms) in NR1 format
The :MEASure:PWIDth command installs a screen measurement and starts the
positive pulse width measurement. If the optional source parameter is specified,
the current source is modified.
This command is not available if the source is FFT (Fast Fourier Transform).
NOTE
Query Syntax
:MEASure:PWIDth? [<source>]
The :MEASure:PWIDth? query measures and outputs the width of the displayed
positive pulse closest to the trigger reference. Pulse width is measured at the
midpoint of the upper and lower thresholds.
IF the edge on the screen closest to the trigger is falling:
THEN width = (time at trailing falling edge - time at leading rising edge)
ELSE width = (time at leading falling edge - time at leading rising edge)
Return Format
<value><NL>
<value> ::= width of positive pulse in seconds in NR3 format
See Also
522
(see
page
1428)
| WMEMory<r>}
"Introduction to :MEASure Commands"
":MEASure:SOURce"
on page 529
":MEASure:NWIDth"
on page 514
":MEASure:PERiod"
on page 518
on page 488
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InfiniiVision MSO-X 4022A and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Infiniivision 4000 x seriesInfiniivision mso-x 4032aInfiniivision mso-x 4034aInfiniivision mso-x 4054aInfiniivision mso-x 4104aInfiniivision mso-x 4154a ... Show all

Table of Contents