Sign In
Upload
Manuals
Brands
Festo Manuals
Industrial Equipment
CPX-FB37
Festo CPX-FB37 Manuals
Manuals and User Guides for Festo CPX-FB37. We have
2
Festo CPX-FB37 manuals available for free PDF download: Translation Of The Original Instructions, Manual
Festo CPX-FB37 Translation Of The Original Instructions (88 pages)
Brand:
Festo
| Category:
Touch terminals
| Size: 3.41 MB
Table of Contents
Table of Contents
3
1 Safety
7
General Safety Information
7
Intended Use
7
Requirements for Product Use
9
Technical Requirements
9
Qualification of Specialists (Personnel Requirements)
9
Range of Application and Certifications
9
2 Overview
10
Function Range (Brief Overview)
10
Connections and Display Components
11
3 Mounting and Installation
12
Dismantling and Mounting
12
Dismantling the Bus Node
13
Mounting the Bus Node
14
Setting the DIL Switches on the Bus Node
15
Removing and Fitting the Cover over the DIL Switches
15
Arrangement of the DIL Switches
16
Setting the DIL Switches
16
Setting the Operating Mode
17
Configuring the Ethercat Addressing Type
17
Setting the Diagnostics Mode (Remote I/O Operating Mode)
18
Setting the I/O Mode (Remote Controller Operating Mode)
19
Starting the Bootloader Mode
19
Setting the Ethercat Address
20
Connecting to the Ethercat Network
22
General Notes on Ethercat Networks
22
Network Interface
23
Network Connectors
23
Cable Specification
23
Complying with Degree of Protection IP65/IP67
24
Voltage Supply
24
4 Commissioning
26
General Instructions
26
Switching on the Power Supply
26
Addressing, Configuration and Parameterisation
26
Address Assignment
26
Addressing the Inputs and Outputs, Data Access
27
Basic Rules for Addressing
27
Differences in Addressing between the Modular Device Profile and Fixed I/O Size
27
Data Access (Data Objects)
28
Addressing the Devices
28
Assigning an Independent Ethercat Device Address Via DIL Switch
28
Assigning an Independent Ethercat Device Address Using the Configuration Tool
28
Configuration
30
Registering Station Properties in the Configuration Program
30
Configuration in the Modular Device Profile (MDP)
32
Configuration with Fixed I/O Size (CPX-FB38 Mode)
35
Configuration in the Remote Controller Operating Mode
35
Parameterisation
37
Introduction to Parameterisation
37
Methods of Parameterisation
38
Parameterisation with the Operator Unit CPX-MMI
38
Parameterisation with the Festo Maintenance Tool (CPX-FMT)
38
Parameterisation Via Ethercat in the Modular Device Profile (MDP)
39
Remarks on Parameters of the CPX System Settings
41
Sequence of Start Parameterisation During Switch-On (System Start)
41
Parameterisation of the Fail-Safe Mode
42
Web Server
44
Configuration
44
Firmware Update/Restoring the Firmware
50
Updating the Firmware Via Foe (File Access over Ethercat)
50
Restoring the Firmware with the Festo Field Device Tool (FFT)
52
Checklist for Commissioning a CPX Terminal
53
Replacing the Bus Node
54
5 Diagnostics
55
Summary of Diagnostics Options
55
Diagnostics Via Leds
56
Leds at the Bus Node CPX-FB37
56
Normal Operating Status
57
CPX-Specific Leds
58
Ethercat-Specific Leds
61
Diagnostics Via Status Bits
64
Diagnostics Via the I/O Diagnostic Interface (STI)
65
Diagnostics Via Ethercat
66
Basic Information
66
Diagnostics Via SDO Access
66
Diagnostics Via Diagnostics History
66
Die Emergency Message
73
Error Characteristics (Fail-Safe Mode)
75
Error Types
76
A Technical Appendix
77
Technical Data
77
Object Directories
78
Object Directory CPX-FB37 Mode (Modular Device Profile)
78
Object Directory CPX-FB38 Mode (Fixed I/O Size)
81
B Glossary
83
Advertisement
Festo CPX-FB37 Manual (3 pages)
Brand:
Festo
| Category:
Industrial Equipment
| Size: 0.17 MB
Advertisement
Related Products
Festo CPX-AP-A
Festo CPX-AP-A-4IOL-M12
Festo CP System
Festo CPE24-PRSE-2
Festo CPE18-PRS-EP
Festo CP-AM-MEAS
Festo CP-AM-MEASURE-V2
Festo CP Lab Conveyor
Festo CP Factory Shunt
Festo CP Factory Bypass
Festo Categories
Industrial Equipment
Control Unit
Controller
Touch terminals
DC Drives
More Festo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL