Operation; Address Assignment; Parameterisation - Festo VABA-S6-1-AP Operating Instructions Manual

Table of Contents

Advertisement

Operation

8
Operation
8.1

Address assignment

– A maximum of 24 solenoid coils can be actuated.
– Valve position 0 is located on the left-hand side.
– Address assignment is in ascending order without gaps, from left to right.
– Address assignment does not depend on whether the module is equipped with blanking plates.
– A valve location can occupy up to two addresses. The following allocation applies here:
– Solenoid coil for switching position 14: lower-value address
– Solenoid coil for switching position 12: higher-value address
1
2
Fig. 2: Example of address assignment with 12
valve positions
8.2

Parameterisation

Various parameters are available for reading out information about the modules in an automation
system CPX-AP and adapting the modules to the application situation.
8
4
1
Example of valve position 0:
Solenoid coil SP1 (address 0)
Solenoid coil SP2 (address 1)
2
Blanking plate
3
Addresses of the solenoid coils 14
4
Addresses of the solenoid coils 12
3
Festo — VABA-S6-1-AP — 2022-06