:BUS<n>:RS232 (Option)
Command List:
:BUS<n>:RS232:BAUD
:BUS<n>:RS232:BUSer
:BUS<n>:RS232:DBITs
:BUS<n>:RS232:ENDian
:BUS<n>:RS232:OFFSet
:BUS<n>:RS232:PACKet
:BUS<n>:RS232:PARity
:BUS<n>:RS232:PEND
:BUS<n>:RS232:POLarity
:BUS<n>:RS232:RTHReshold
:BUS<n>:RS232:RX
:BUS<n>:RS232:SBITs
:BUS<n>:RS232:TTHReshold
:BUS<n>:RS232:TX
:BUS<n>:RS232:BAUD
Syntax
:BUS<n>:RS232:BAUD <baud>
:BUS<n>:RS232:BAUD?
Description
Sets or queries the baud rate of data of RS232 decoding on the specified bus. The default unit is bps.
Parameter
Name
Type
<n>
Discrete
<baud>
Discrete
Remarks
When <baud> is set to "USER", you can use the :BUS<n>:RS232:BUSer command to self-define the signal
rate of RS232 decoding on the specified bus.
Return Format
The query returns an integer or USER.
:BUS<n>:RS232:BUSer
Syntax
:BUS<n>:RS232:BUSer <baud>
:BUS<n>:RS232:BUSer?
Description
Sets or queries the user-defined baud rate of data of RS232 decoding on the specified bus. The default unit
is bps.
Parameter
Name
Type
<n>
Discrete
<baud>
Integer
DS4000E Programming Guide
Range
{1|2}
{2400|4800|9600|19200|38400|57600|115200|
230400|460800|921600|1000000|USER}
Range
{1|2}
11 to 20000000
RIGOL
Default
--
9600
Default
--
9600
2-23