Measure:preshoot - Rigol DS4000E Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for DS4000E Series:
Table of Contents

Advertisement

RIGOL
:MEASure:PERiod:SAVerage
:MEASure:PERiod:SCURrent
:MEASure:PERiod:SDEViation
:MEASure:PERiod:SMAXimum
:MEASure:PERiod:SMINimum
Syntax 1
:MEASure:PERiod:SAVerage [<chan>]
:MEASure:PERiod:SCURrent [<chan>]
:MEASure:PERiod:SDEViation [<chan>]
:MEASure:PERiod:SMAXimum [<chan>]
:MEASure:PERiod:SMINimum [<chan>]
Description 1
Measures the period of the specified source channel and enables the statistic function of the measurement
results.
Syntax 2
:MEASure:PERiod:SAVerage? [<chan>]
:MEASure:PERiod:SCURrent? [<chan>]
:MEASure:PERiod:SDEViation? [<chan>]
:MEASure:PERiod:SMAXimum? [<chan>]
:MEASure:PERiod:SMINimum? [<chan>]
Description 2
Queries the average value, current value, standard deviation, maximum value, or minimum value of the
period measurement results when the period measurement function of the specified source channel and
the statistic function of the measurement results are enabled. The default unit is s.
Parameter
Name
Type
<chan>
Discrete
Remarks
Before making measurements, turn on the channels to be measured.
When the math operation type is FFT (refer to the :CALCulate:MODE command), <chan> cannot be
set to "MATH".
When [<chan>] is omitted, the command, by default, applies to the currently set measurement source
(refer to the :MEASure:SOURce command).
Return Format
The query returns the average value, current value, standard deviation, maximum value, or minimum value
in scientific notation. When the measurement results are invalid, the query returns 9.9e37.

:MEASure:PREShoot

Syntax 1
:MEASure:PREShoot [<chan>]
Description 1
Measures the preshoot of the specified source channel.
Syntax 2
:MEASure:PREShoot? [<chan>]
2-138
Range
{CHANnel1|CHANnel2|CHANnel3|CHANnel4|MATH}
Chapter 2 Command System
Default
--
DS4000E Programming Guide