Measure:setup:dsa; Measure:setup:dsb; Measure:setup:max; Measure:setup:mid - Rigol DS4000E Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for DS4000E Series:
Table of Contents

Advertisement

Chapter 2 Command System

:MEASure:SETup:DSA

:MEASure:SETup:DSB

Syntax
:MEASure:SETup:DSA <sourA>
:MEASure:SETup:DSA?
:MEASure:SETup:DSB <sourB>
:MEASure:SETup:DSB?
Description
Sets or queries the channel source of Source A or Source B in delay measurement.
Parameter
Name
Type
<sourA>
Discrete
<sourB>
Discrete
Remarks
The delay measurement function is used to measure the following four kinds of delays between the
specified channels:
Source A rising edge-Source B rising edge (refer to the :MEASure:RDELay command)
Source A rising edge-Source B falling edge (refer to the :MEASure:R2FDelay command)
Source A falling edge-Source B falling edge (refer to the :MEASure:FDELay command)
Source A falling edge-Source B rising edge (refer to the :MEASure:F2RDelay command)
Return Format
The query returns CHAN1, CHAN2, CHAN3, or CHAN4.

:MEASure:SETup:MAX

:MEASure:SETup:MID

:MEASure:SETup:MIN

Syntax
:MEASure:SETup:MAX <max>
:MEASure:SETup:MAX?
:MEASure:SETup:MID <mid>
:MEASure:SETup:MID?
:MEASure:SETup:MIN <min>
:MEASure:SETup:MIN?
Description
Sets or queries the upper limit, middle value, and lower limit (in percentage) of the threshold in the auto
measurement of the analog channel.
Parameter
Name
Type
<max>
Integer
<mid>
Integer
<min>
Integer
DS4000E Programming Guide
Range
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
Range
7 to 95
6 to 94
5 to 93
RIGOL
Default
CHANnel1
CHANnel2
Default
90
50
10