Chapter 2 Command System

:TRIGger:CAN

Command List:
:TRIGger:CAN:BAUD
:TRIGger:CAN:BUSer
:TRIGger:CAN:FTYPe
:TRIGger:CAN:LEVel
:TRIGger:CAN:SOURce
:TRIGger:CAN:SPOint
:TRIGger:CAN:STYPe
:TRIGger:CAN:WHEN
:TRIGger:CAN:BAUD
Syntax
:TRIGger:CAN:BAUD <baud>
:TRIGger:CAN:BAUD?
Description
Sets or queries the signal rate of CAN trigger. The default unit is b/s.
Parameter
Name
Type
<baud>
Discrete
Remarks
When <baud> is set to "USER", you can use the :TRIGger:CAN:BUSer command to self-define the signal
rate of CAN trigger.
Return Format
The query returns 10000, 20000, 33300, 50000, 62500, 83300, 100000, 125000, 250000, 500000, 800000,
1000000, or USER.
:TRIGger:CAN:BUSer
Syntax
:TRIGger:CAN:BUSer <baud>
:TRIGger:CAN:BUSer?
Description
Sets or queries the user-defined signal rate of CAN trigger. The default unit is b/s.
Parameter
Name
Type
<baud>
Integer
Return Format
The query returns an integer between 10000 and 10000000.
DS4000E Programming Guide
Range
{10000|20000|33300|50000|62500|83300|100000|
125000|250000|500000|800000|1000000|USER}
Range
10000 to 1000000
RIGOL
Default
10000
Default
10000