Chapter 5 To Trigger the Oscilloscope
Trigger Condition:
Press When to select the desired trigger condition.
SOF: triggers at the start of a frame.
EOF: triggers at the end of a frame.
Remote ID: triggers on the remote frame with the specified ID. Set the following
parameters:
Overload: triggers on the CAN overload frames.
Frame ID: triggers on the data frames with the specified ID. Set the following
parameters:
Frame Data: triggers on the data frames with specified data. Set the following
parameters:
Data&ID: triggers on the data frames with the specified ID and data. Set the
following parameters:
Frame Error: triggers on the error frame.
Bit Fill: triggers on the error frame with the bit fill.
Answer Error: triggers on the answer error frame.
Check Error: triggers on the check error frame.
Format Error: triggers on the format error frame.
Random Error: triggers on random error frame, such as the format error frame,
answer error frame, etc.
Signal Type:
Press More  Signal Type to select the desired signal type.
CAN_H: indicates the actual CAN_H bus signal.
CAN_L: indicates the actual CAN_L bus signal.
TX/RX: indicates the Transmit signal and Receive signal from the CAN bus
transceiver.
DIFF: The CAN differential bus signals connected to an analog source channel by
using a differential probe. Connect the probe's positive lead to the CAN_H bus
signal and connect the negative lead to the CAN_L bus signal.
MSO5000 User's Guide
nd Quality Products Online at:
Press Extended ID to enable or disable the extended ID.
Press Bit X to set the data bit that needs to be operated on. For setting
methods, refer to descriptions in "I2C Trigger (Option)".
Press Extended ID to enable or disable the extended ID.
Press Bit X to set the data bit that needs to be operated on. For setting
methods, refer to descriptions in "I2C Trigger (Option)".
Press Bit X to set the data bit that needs to be operated on. For setting
methods, refer to descriptions in "I2C Trigger (Option)".
Press Bytes, then rotate the multifunction knob
keypad to set the length of the data. Its range is from 1 to 8.
Press Define to select "Data" or "ID".
When you select "Data", set Bit X and Bytes. For detailed settings, refer to
parameter settings for "Frame Data".
When you select "ID", set Extended ID and Bit X. For detailed settings,
refer to parameter settings for "Frame ID".