Note
To disconnect the alternator harness from the regulator/rectifier, the rear
mudguard has to be removed.
Note the routing of the alternator harness, crankshaft position sensor harness
and starter motor cable for installation.
5.
Remove the rear mudguard and detach the alternator harness from the
regulator/rectifier (see Rear Mudguard - Removal).
6.
Detach the crankshaft position sensor electrical connector from the rear of the
airbox. Disconnect the crankshaft position sensor from the main harness.
7.
Disconnect the starter motor lead from the starter motor solenoid.
8.
Route the three cables down to the engine.
9.
Release the two hose clips and remove the engine breather hose.
Service Manual - Scrambler 1200 XC
L0810
2
ckjp
1.
Crankshaft position sensor electrical connector
2.
Starter motor lead
1
1