Output Attenuation Block

Double-click the output
Figure 101.
The
Attenuation
Figure 102.
Output Name — This name changes to match the default or user defined output name.
1
Output Attenuation Fader — Click and drag the trim fader to provide up to 100 dB of
2
attenuation. Click the trim fader and use the <
the fader up or down in 1 dB steps.
Output Attenuation Text Box — Allows the user to enter a gain or attenuation value in
3
0.1 dB steps.
dBFS Meter — Provides post-attenuation and pre-mute a readout of the output signal
4
level.
dBFS Text Readout — Displays a numerical readout of the output signal level.
5
Polarity Button — Click this button to invert the signal polarity of the selected output.
6
When the button displays the black
When the button displays the black
inverted.
Mute Button — Mutes the signal at the output stage.
7
OK Button — Confirms changes made to the contained parameters and closes the
8
Attenuation
Cancel Button — Reverts any changes made to the contained parameters back to
9
their states when the current instance of the
closes the dialog box.
block to open the
Attenuation
Output Attenuation Block
dialog box provides attenuation control for the selected output.
Output Name
1
Output Attenuation Fader
2
Output Attenuation Text Box
3
dBFS Meter
4
dBFS Text Readout
5
Attenuation Dialog Box
+
-
dialog box.
DMP 128 FlexPlus • DSP Configurator Software
Attenuation
Polarity Button
6
Mute Button
7
OK Button
8
Cancel Button
9
> or <
Up Arrow
Down Arrow>
symbol on a gray field ( ), the polarity is normal.
symbol on a yellow field ( ), the polarity is
dialog box was opened and
Attenuation
dialog box.
to adjust