Extron electronics DMP 128 FlexPlus User Manual page 57

Prodsp digital matrix processor
Hide thumbs Also See for DMP 128 FlexPlus:
Table of Contents

Advertisement

Settings Tab
Figure 81.
Feedback Suppressor Dialog Box - Settings Tab
Settings Tab — Provides access to the global FBS settings.
1
Composite View Panel — Three radio buttons control which filters are displayed in the
2
filter graph:
Only Dynamic FBS Filters
Only Fixed FBS Filters
Fixed & Dynamic FBS Filters (default)
Filter Graph — Displays the dynamic filters, fixed filters, or both, as selected in the
3
panel.
Composite View
Q Adjustment Panel — Adjust the default
4
text box or the up/down spinner controls.
Attack Time Panel — Adjust the default
5
Hold Time Panel — Provides an
6
parameter. Entering a time into the
filter will hold before removing the filter.
Bypass FBS — Turns off feedback detection when bypass is engaged (button is red
7
when bypass is engaged). Only the dynamic filters are bypassed. Fixed filters remain
active.
Set Defaults Button — Resets parameters on all tabs to their default values and
8
positions.
OK Button — Confirms changes made to the contained parameters and closes the
9
Feedback Suppressor
Cancel Button — Reverts any changes made to the contained parameters back to
¢
their states when the current instance of the
opened and closes the dialog box.
parameter of the dynamic filters using the
Q
Attack Time
checkbox, that enables the
Enable
text boxes sets how long each dynamic
Hold Time
dialog box.
Feedback Suppressor
DMP 128 FlexPlus • DSP Configurator Software
Settings Tab
1
Composite View Panel
2
Filter Graph
3
Q Adjustment Panel
4
Attack Time Panel
5
Hold Time Panel
6
Bypass FBS Button
7
Set Defaults Button
8
OK Button
9
Cancel Button
¢
for dynamic filters.
Hold Time
dialog box was
48

Advertisement

Table of Contents
loading

Table of Contents