Chapter VII. WD-TOE

Software/Driver Configuration and Fine-tuning

4.1.

Running the Application

i.
Bring up the Chelsio interface to enable offload:
[root@host~]# ifconfig ethX <IP> up
ii. Run the application with WD-TOE using:
[root@host~]# PROT=TCP wdload <path to application>
Netperf, sockperf and IPerf only supported.
Note
Maximum of 10 connections supported.
Abrupt killing of connections is not supported.
Message size should be less than 1500.
Short-lived connections not supported.
Multi-threaded applications not supported.
Jumbo frames not supported.
Multiple adapters not supported.
Example: To run Netperf application with WD-TOE:
Start netserver at the PEER:
[root@host~]# PROT=TCP wdload netserver –D -4
On the Test machine, run netperf application.
[root@host~]# PROT=TCP wdload netperf -H <PEER_IP> -t TCP_RR -l 10