Connecting the motor holding brake
The Motor Holding Brake (MHB) function of the Control Units comprise dedicated hardware
and software to control the actions of the MHB on the motor which is connected to the
Inverter.
The MHB is connected to the Inverter using the EMB- and EMB+ terminals of the mains
connectors in the Control Unit housing. The Power Module must be removed to access
these terminals.
When the motor holding brake is connected to the Inverter , 180 V DC (at 400 VAC mains
voltage) is supplied to the motor holding brake and the software within the Inverter monitors
the correct functioning of the brake.
Figure 4-15
4.3.7

Connecting the PROFINET interface

Industrial Ethernet Cables and cable length
Listed in the table below are the recommended Ethernet cables.
Table 4- 7
Cable type
Industrial Ethernet FC TP Standard Cable GP 2 x 2
Industrial Ethernet FC TP Flexible Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable 2 x 2
Industrial Ethernet FC Marine Cable 2 x 2
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH
Simplied diagram of the motor holding brake connections
Recommended PROFINET cables
4.3 Electrical Installation
Max. length be-
Article Number
tween devices
100 m (328 ft)
6XV1840-2AH10
85 m (278 ft)
6XV1870–2B
85 m (278 ft)
6XV1870–2D
85 m (278 ft)
6XV1840–3AH10
85 m (278 ft)
6XV1840–4AH10
Installation