Most Common I/O
Most Common I/O is used in the Program Editor to display a list of the most
commonly used I/O signals in the robot system. Since there can be many signals,
it can be helpful to use this selection.
The sorting in the list can be rearranged manually. By default, the signals are sorted
in the order that they are created.
Most Common I/O can also be configured using system parameters in the topic
Man-machine Communication. However, sorting the list can only be done by using
the function under the Control Panel.
Configuring Most Common I/O
Use this procedure to configure the list Most Common I/O.
1
2
3
4
5
114
Action
On the ABB menu, tap Control Panel.
Tap I/O.
A list of all I/O signals defined in the system is listed with check boxes.
Tap the names of the signals to select for the Most Common I/O list.
Tap All or None to select all or no signals.
Tap Name or Type to sort by name or signal type.
Tap Preview to see the list of selected signals and adjust the sort order.
Tap to select a signal and then tap the arrows to move the signal up or down in the
list, rearranging the sort order.
Tap APPLY to save the sort order.
Tap Edit to return to the list of all signals.
Tap APPLY to save the settings.