4 Software commissioning

4.3 Configuring Scalable I/O devices using RobotStudio

4.3 Configuring Scalable I/O devices using RobotStudio
General
This section describes the recommended working procedure when installing and
configuring ABB Scalable I/O devices in RobotStudio.
For information about configuration using the FlexPendant, see
I/O devices using the FlexPendant on page
When the I/O device is configured using Plug & Produce interface, it requires
minimal user interaction. Follow the working procedures to configure a new I/O
device, update an existing I/O device and to replace an I/O device with another.
Configuring an I/O device
When a base I/O device and an add-on I/O device are connected to the controller,
they must be configured.
This procedure describes how to configure the base I/O device and add-on I/O
device at the same time. However, if more add-on I/O devices should be attached
after the first configuration of the base I/O device, use the
device on page 60
Continues on next page
58
Note
Safe digital base devices (DSQC1042) cannot be configured using the
FlexPendant.
The Safety services grant is mandatory for configuration of safe digital base
devices.
Note
A maximum of 4 safe scalable I/O devices can be used at the same time with an
OmniCore controller.
procedure to update the configuration of the base I/O device.
1 Start RobotStudio and connect to the OmniCore controller. Request write
access.
2 The I/O device that has not yet been configured is connected to the private
network. The name of the detected I/O device appears.
xx2100000064
3 Right-click the detected I/O device and select Configure.