7 Handling inputs and outputs, I/O

7.2 Simulating and changing signal values

7.2 Simulating and changing signal values
Simulating and changing signal values
A signal can be changed into a simulated signal. The value of the signal can also
be changed.
Use the following procedure to simulate a signal or to change the value of a signal:
1
2
3
4
5
Continues on next page
276
Action
On the ABB menu, tap Inputs and Outputs.
A list of most common signals is displayed. See section
I/O on page
114.
Tap View and select a signal filter.
The signal list is updated.
xx1700002252
Note
Tap All Signals to view all the signals.
Tap on a signal.
Tap on Simulate to change the signal into a simulated signal.
Tap on Remove Simulation to remove the simulation from the signal.
Note
When you remove the simulation from a signal, the signal value returns to the same
value it had before it was simulated. Also the cross connections are updated accord-
ingly.
For a digital signal, tap 0 or 1 to change the value of a signal.
For analog signals and groups, tap on 123... to change the signal value. The soft nu-
meric keyboard is displayed. Enter the new value and tap OK.
Note
If there is a cross connection created between two signals, changing the value of one
signal automatically changes the value of the corresponding cross connected signal.
© Copyright 2018 ABB. All rights reserved.
Configuring Most Common
Operating manual - IRC5 with FlexPendant
3HAC050941-001 Revision: G