Reduction Gear Starter; Alternator Specifications - Dodge D150 1990 Service Manual

Rear wheel drive ram truck
Table of Contents

Advertisement

BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS
8A - 19
S P E C I F I C A T I O N S
BATTERY SPECIFICATIONS
Load
Tost
(Amps)
Cold
Cranking
Rating @ 0°F
Reserve
Capacity
200 Amp
400 Amp
100 Minutes
250 Amp
500 Amp
110 Minutes
315 Amp
625 Amp
120 Minutes
350 Amp
700 Amp
120 Minutes
CRANKING RATING is the current a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2
volts or greater at specified temperature.
RESERVE CAPACITY RATING is the length of ti m e a battery can deliver 25 amps and maintain a mi n i m um terminal voltage of 10.5
volts at 27°C (80°F).
J908A-11
REDUCTION GEAR STARTER
Manufacturer
Nippondenso
5.91, 5.2L & 3.9L
Part Number and
4379160
1.4 Kw
12
No. of Fields
. . . . . . . . . . . . . . . .
4
4
4
Conventional
Gear Train
Free Running Test
Voltage
11
82 Amps
3625 rpm
7.5 Volts
Cranking Amperage Draw Test . . .
150-220 Amps*
* Engine should be up to operating temperature. Extremely heavy
oil or tight engine will increase starter amperage draw.
J908B-6
ALTERNATOR SPECIFICATIONS
TYPE
PART N U M B E R
PULLEY G R O O V E S
E N G I N E
RATING
NIPPONDENSO
5234026
2
ALL
35/75 AMPS
NIPPONDENSO
5234199
2
ALL
50/120 AMPS
NIPPONDENSO
5234028
2
ALL
40/90 AMPS
BOSCH
5235028
2
ALL
40/90 AMPS
J908C-22