Parameters of the function inputs
Name
ENABLE
REPEATTIME
READ_INPUTS
WRITE_OUTPUTS
ANALOG_INPUTS
ifm
System Manual
ecomatmobile
Data type
Description
BOOL
TRUE (only 1 cycle):
FALSE: changes to data not allowed
TIME
Time window during which the interrupt is triggered.
BOOL
TRUE: inputs integrated into the routine are read (if
necessary, set inputs to IN_FAST).
FALSE: inputs integrated into the routine are not read.
BOOL
TRUE: outputs integrated into the routine are written to.
FALSE: outputs integrated into the routine are not written to.
BOOL
TRUE: Analogue inputs integrated into the routine are read
and the raw value of the voltage is transferred to the system
flags ANALOG_IRQxx.
FALSE: Analogue inputs integrated into the routine are not
read.
SmartController (CR2500) V05
changes to data allowed
(during processing of the program)
Processing interrupts