CAN in the ecomatmobile controller
Example:
Parameters of the function inputs
Name
GLOBAL_START
CLEAR_RX_OVERFLOW_FLAG
CLEAR_RX_BUFFER
CLEAR_TX_OVERFLOW_FLAG
CLEAR_TX_BUFFER
CLEAR_RESET_FLAG
ifm
System Manual
ecomatmobile
Data type
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
SmartController (CR2500) V05
Description
TRUE: all connected network participants (slaves) are
started simultaneously during network initialisation.
FALSE: the connected network participants are started
one after the other.
Further information → chapter Starting the network with
GLOBAL_START (→ page 96)
FALSE → TRUE (edge):
Delete error flag "receive buffer overflow"
FALSE: function is not executed
FALSE → TRUE (edge):
Delete data in the receive buffer
FALSE: function is not executed
FALSE → TRUE (edge):
Delete error flag "transmit buffer overflow"
FALSE: function is not executed
FALSE → TRUE (edge):
Delete data in the transmit buffer
FALSE: function is not executed
FALSE → TRUE (edge):
Delete the flags "nodes reset" and "communications
interface reset".
FALSE: function is not executed
ifm CANopen library