CAN in the ecomatmobile controller
Object 1001
(error register)
16
This object reflects the general error state of a CANopen device. The device is to be considered as
error free if the object 1001
Bit
Meaning
0
Generic error
1
Current error
2
Voltage error
3
Temperature error
4
Communication error
5
Device profile specific
6
Reserved – always 0
7
Manufacturer specific
Manufacturer specific information
A device manufacturer can indicate additional error information. The format can be freely selected.
Example:
In a device two errors occur and are signalled via the bus:
- Short circuit of the outputs:
Error code 2300
the value 03
16
(generic error and current error)
- CAN overrun:
Error code 8110
the value 13
16
(generic error, current error and communication error)
>> CAN overrun processed:
Error code 0000
the value 03
16
(generic error, current error, communication error reset)
It can be seen only from this information that the communication error is no longer present.
116
ifm
System Manual
ecomatmobile
signals no error any more.
16
,
16
(0000 0011
) is entered in the object 1001
2
,
16
(0001 0011
) is entered in the object 1001
2
,
16
(0000 0011
) is entered in the object 1001
2
SmartController (CR2500) V05