IFM Electronic Ecomat Mobile Series System Manual page 141

Smart controller
Table of Contents

Advertisement

CAN in the ecomatmobile controller
Example:
Parameters of the function inputs
Name
ENABLE
NODE
IDX
SUBIDX
DATA
Parameters of the function outputs
Name
RESULT
LEN
ifm
System Manual
ecomatmobile
Data type
Description
BOOL
TRUE: function is executed
FALSE: function is not executed
BYTE
Number of the node
WORD
Index in object directory
BYTE
Sub-index referred to the index in the object directory
DWORD
Address of the receive data array
Permissible length = 0...255
Transmission with ADR operator
Data type
Description
BYTE
0 = function inactive
1 = execution of the function completed
2 = function active
3 = function has not been executed
WORD
Length of the entry in "number of bytes"
The value for LEN must correspond to the length of the
receive array. Otherwise, problems with SDO communication
will occur.
SmartController (CR2500) V05
ifm CANopen library
141