IFM Electronic Ecomat Mobile Series System Manual page 193

Smart controller
Table of Contents

Advertisement

PWM in the ecomatmobile controller
Parameters of the function outputs
Name
OUT1
OUT2
OUT3
WRONG_MODE
ERR1
ERR2
ifm
System Manual
ecomatmobile
Data type
Description
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve left
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve right
INT
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve on output module
(e.g. CR2011 or CR2031)
BOOL
Error: invalid mode
BYTE
Error code for rising edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
BYTE
Error code for falling edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
SmartController (CR2500) V05
Hydraulic control in PWM
193

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecomat 100 cr2500

Table of Contents