IFM Electronic Ecomat Mobile Series System Manual page 102

Smart controller
Table of Contents

Advertisement

ifm
System Manual
ecomatmobile
SmartController (CR2500) V05
CAN in the ecomatmobile controller
ifm CANopen library
BaudRate_50=1
BaudRate_100=1
BaudRate_125=1
BaudRate_250=1
BaudRate_500=1
BaudRate_800=1
BaudRate_1000=1
SimpleBootUpMaster=1
SimpleBootUpSlave=0
ExtendedBootUpMaster=1
ExtendedBootUpSlave=0
...
[1018sub0]
ParameterName=Number of entries
ObjectType=0x7
DataType=0x5
AccessType=ro
DefaultValue=2
PDOMapping=0
[1018sub1]
ParameterName=VendorID
ObjectType=0x7
DataType=0x7
AccessType=ro
DefaultValue=0x0
PDOMapping=0
[1018sub2]
ParameterName=Product Code
ObjectType=0x7
DataType=0x7
AccessType=ro
DefaultValue=0x0
PDOMapping=0
For the meaning of the individual objects please see the CANopen specification DS301.
In addition to the prescribed entries, the EDS file contains the definitions for SYNC, guarding,
emergency and heartbeat. If these objects are not used, the values are set to 0 (preset). But as the
objects are present in the object directory of the slave at runtime, they are written to in the EDS file.
The same goes for the entries for the communication and mapping parameters. All 8 possible sub-
indices of the mapping objects 16xx
or 1Axx
are present, but possibly not considered in the sub-
16
16
index 0.
NOTE: Bit mapping is not supported by the library!