PWM in the ecomatmobile controller
Characteristics of the function
Parameters of the function inputs
Name
X
XH
XL
YH
YL
Parameters of the function outputs
Name
Y
X_OUT_OF_RANGE
198
ifm
System Manual
ecomatmobile
Data type
Description
DINT
Desired value input
DINT
Max. input value [increments]
DINT
Min. input value [increments]
DINT
Max. output value [increments], e.g.:
valve current [mA] / flow [l/min]
DINT
Min. output value [increments], e.g.:
valve current [mA] / flow [l/min]
Data type
Description
DINT
Standardised output value
BOOL
Error: X is beyond the limits XH and XL
SmartController (CR2500) V05