IFM Electronic Ecomat Mobile Series System Manual page 196

Smart controller
Table of Contents

Advertisement

PWM in the ecomatmobile controller
Parameters of the function outputs
Name
OUT1
OUT2
OUT3
ERR1
ERR2
196
ifm
System Manual
ecomatmobile
Data type
Description
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve left
WORD
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve right
INT
Standardised output value
pairs of values 0 to 10 [increments]
e.g. for valve on output module
(e.g. CR2011 or CR2031)
BYTE
Error code for rising edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
BYTE
Error code for falling edge:
0 = no error
1 = error in array: wrong sequence
2 = initial value IN not contained in value range of array
4 = invalid number N for array
SmartController (CR2500) V05