More functions in the ecomatmobile controller
Parameters of the function inputs
Name
ENABLE
INIT
CHANNEL
MODE_UP_DOWN
LOAD
PV
NOTE
After setting the parameter ENABLE the counter counts as from the indicated start value.
The counter does NOT continue from the value which was valid at the last deactivation of ENABLE.
Parameters of the function outputs
Name
CV
214
ifm
System Manual
ecomatmobile
Data type
Description
BOOL
TRUE: function is executed, starting from the start value.
FALSE: function is not executed.
BOOL
TRUE (only 1 cycle):
FALSE: during cyclical processing of the program.
BYTE
number of the input (0...3).
BOOL
TRUE: counter counts downwards.
FALSE: counter counts upwards.
BOOL
TRUE: start value PV being loaded.
FALSE: start value "0" being loaded.
WORD
Start value (preset value).
Data type
Description
WORD
output value of the counter.
SmartController (CR2500) V05
Counter functions for frequency and period measurement
function initialised.