Ejecting Cartridges through the PCAP
The PCAP is on the enhanced access door. A cartridge is ejected from a PCAP when a
message appears on the console to eject the cartridge. Use the eject command to eject
cartridges from an LSM. Refer to the appropriate software manual for the command
syntax and console messages.
1. Type the eject command at the console.
Locked appears on the display, if it is not already there.
The robot places a cartridge into the CAP.
Remove Cartridge
Eject replaces Locked on the display.
CAUTION:
ROBOT/MEDIA DAMAGE. Make sure that Eject appears on the display
before you open the CAP.
2. Open the PCAP door.
3. Remove the cartridge from the PCAP slot.
4. Close the PCAP door. Locked replaces Eject and Remove Cartridges on
the display.
5. If more cartridges need to be ejected, the robot continues filling the PCAP. Wait until
the PCAP door is unlocked and repeat step
The eject operation ends automatically when all specified cartridges have been ejected.