T9x40 Cartridge Environmental Specifications
The following specifications refer to the operating and storage environments for T9x40
cartridges:
Operating environment:
Temperature
Relative humidity
Wet bulb temperature
Cartridge storage (non-archive) environment:
Temperature
Relative humidity
Wet bulb temperature
Cartridge storage (archive) environment:
Temperature
Relative humidity
Wet bulb temperature
Storing Cartridges
When you store a cartridge:
•
Do not take a cartridge out of its protective wrapping until you are ready to use it.
Use the tear string, not a sharp instrument, to remove the wrapping.
•
Store cartridges in a clean environment that duplicates the conditions of the room in
which they are used.
•
Before you use a cartridge, make sure that it has been in its operating environment at
least 24 hours.
9206
15.6º to 32.2ºC (60º to 90ºF)
20% to 80%
26ºC (78.8ºF) maximum
5º to 32.2ºC (41º to 90ºF)
5% to 80%
26ºC (78ºF) maximum
5º to 25.5ºC (41º to 78ºF)
40% to 60%
26ºC (78ºF) maximum
Eleventh Edition
Maintaining Cartridges
A-17