ICP DAS USA UA-5200 Series User Manual page 58

Iiot communication server
Hide thumbs Also See for UA-5200 Series:
Table of Contents

Advertisement

Step 4. Enable Converting Module
Click the next step, and enter the Step 4 [Enable Converting Module] UI setting
This step is for enabling the MQTT / OPC UA conversion.
We select the "MQTT / OPC UA" conversion at the beginning, so this step will auto
enter the [OPC UA > MQTT] page of Conversion setting. The "Step Box" will prevent
the user from selecting the wrong platform.
Convert Setting > OPC UA > MQTT - MQTT Module List
No.
*Module Name
/ Nickname
Edit
All Enabled
Save
The module number in the module list (Not editable here)
The module name set in the module list (Not editable here)
If user wants to enable some I/O channels for conversion, click
[Edit] of that module to enter the "Variable Tale" setting. It is
normal to set all channels as enabled, and the conversion will not
affect the unconnected channels.
Check [All Enabled] box to enable all modules in list for
conversion. Default: Uncheck.
Check the box of each module can enable just that module for
conversion.
The page number of the module list: Current page / Total pages.
Click < or > to go to the previous or next page.
Click to save the settings of this page.
UA-5200 Series User Manual V4.3
58
ICP DAS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ua-5231m-3gwaUa-5231m-4geUa-5231Ua-5231m-4gcUa-5231m

Table of Contents