Step 9. Enable Converting Module
Click the next step, and enter the Step 3 [Enable Converting Module] UI setting
This step is for enabling the module for the Modbus TCP / MQTT conversion.
We select the "Modbus TCP / MQTT" conversion at the beginning, so this step will auto
enter the [MQTT > Modbus TCP (Master)] page of Conversion setting. The "Step Box"
will prevent the user from selecting the wrong platform.
Convert Setting > MQTT > Modbus TCP (Master) Module List
No.
*Module Name
/ Nickname
All Enabled
Edit
Save
The module number in the module list (Not editable here)
The module name set in the module list (Not editable here)
Check [All Enabled] box to enable all modules in list for
conversion. Default: Uncheck.
Check the box of each module can enable just that module for
conversion.
Click to enter the "MQTT Client Setting" page to set up the Topic,
QoS, Publish, Subscribe ...
The page number of the module list: Current page / Total pages.
Click < or > to go to the previous or next page.
Click to save the settings of this page.
UA-5200 Series User Manual V4.3
69