IoT Platform Setting > MQTT Connection > Microsoft Azure Platform > Azure Content Settings
Azure Name
SAS Token
Keep Alive
Time(second)
Scan Rate(ms)
Dead Band
CDS
(Connected
Device Studio)
OK
Azure name. User can define the name. Default: Name.
Input the SAS Token which you previously registered for the UA
controller from Microsoft Azure. For the procedure to generate a SAS
Token, please refer to the "Documentation > Azure IoT Hub > IoT Hub
MQTT support" section on the Microsoft Azure Web Site for detailed
information.
Set the time in second that pass away without communication
between the UA controller and Microsoft Azure. Default: 60 second.
Set an update frequency for the task data. Default: 1000 (Unit: ms)
Give a dead bend value for updating a float signal. Default: 0
If user wants to publish the messages compliant with the Microsoft
CDS platform, user must check the "CDS" and fill in the Company ID,
Equipment ID and Message ID that applied from the Microsoft CDS
platform. Default: Uncheck.
Click to save and exit this page.
UA-5200 Series User Manual V4.3