PDS-220Fx Series
User Manual
Version 1.2, April 2015
Service and usage information for
PDS-220FT
PDS-220FC
PDS-220FCS-60
PDS-220FCS
1
PDS-220Fx Series User Manual (V1.2, Apr. 2015)

Advertisement

Table of Contents
loading

Summary of Contents for ICP DAS USA PDS-220F Series

  • Page 1 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru PDS-220Fx Series User Manual Version 1.2, April 2015 Service and usage information for PDS-220FT PDS-220FC PDS-220FCS-60 PDS-220FCS PDS-220Fx Series User Manual (V1.2, Apr. 2015)
  • Page 2 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from the date of delivery to the original purchaser. Warning ICP DAS assumes no liability for damages resulting from the use of this product.
  • Page 3: Table Of Contents

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Table of Contents INTRODUCTION ..............................6 ? ......................... 7 IBER PTIC OLUTIONS ? ..........................8 ECHNOLOGY ? ........................10 ERVER ECHNOLOGY TYPICAL APPLICATIONS FOR THE PDS ....................11 RS-232/485/422 D ......................
  • Page 4 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7.3.14 ..............................68 7.3.15 NAME ..............................69 7.3.16 ALIAS ..............................69 7.3.17 DHCP ..............................70 7.3.18 ..............................70 7.3.19 ..............................71 7.3.20 SAVE ..............................71 7.3.21 LOAD ..............................
  • Page 5 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Packing List The package includes the following items:  One PDS-220Fx Series hardware module  One software utility CD  One Quick Start Guide QuickStart Note: If any of these items are missed or damaged, contact the local distributors for more information.
  • Page 6: Introduction

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1. Introduction The PDS-220Fx series is a family of Programmable Device Servers, also known as "Serial-to-Ethernet gateway”, that are designed for adding optical fiber connectivity to RS- 232/422/485 devices.
  • Page 7: Why Fiber Optic Solutions

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1.1 Why Fiber Optic Solutions? The fiber-optic communications permits transmission over longer distances than other forms of communications because of the signals travel along them with less loss and no crosstalk.
  • Page 8: Comm Technology

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1.2 Why VxComm Technology? In general, writing a TCP/IP program is more difficult than a COM port program, or the COM port communication system was built many years ago. As a result, a new technology, VxComm was developed to virtualize the COM ports of the PDS to allow up to 256 COM Ports to be used on the central computer.
  • Page 9 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru The VxComm driver controls all the details of the Ethernet TCP/IP programming technique; your COM port program will be able to access your serial devices through Ethernet in the same way as through COM port with the assistance of PDS-220Fx and VxComm technology.
  • Page 10: Why Web Server Technology

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1.3 Why Web Server Technology? Web server technology enables configuration of the PDS-220Fx series via a standard web browser interface, e.g. Internet Explorer, FireFox or Mozilla, etc. This means that it is easy to check the configuration of the PDS-220Fx series via an Ethernet network without needing to install any other software tools;...
  • Page 11: Typical Applications For The Pds

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2. Typical Applications for the PDS 2.1 RS-232/485/422 Device Networking --- Using Virtual COM Technology --- The PDS-220Fx series is designed to link RS-232/485/422 devices to an Ethernet network. The VxComm utility allows the built-in PDS-220Fx COM Port to be virtualized to a standard COM Port of the host PC as shown below: The original COM1/2...
  • Page 12: Fiber I/O Applications

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2.2 Fiber I/O Applications The PDS-220Fx series provides fiber optic I/O solution: Linking to I-7000 series modules The I-7000 series provides a variety of I/O operations, such as D/I, D/O, A/D, D/A, Counter and Frequency Measurement, etc.
  • Page 13 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Configure the system connection as shown below and click the “Start” button to begin logging data. Open the log file in Excel to read the log data as shown in the example below: PDS-220Fx Series User Manual (V1.2, Apr.
  • Page 14 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru By using the I-7000 DCON utility and MS Excel in conjunction with the VxComm technology, the signal data of I-7000 modules from the fiber optic network can be analyzed without the need to write custom programs.
  • Page 15: Hardware Information

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Hardware Information 3.1 Features  Adds optical fiber connectivity to serial devices  Virtual COM extends the PC COM Ports  Virtual COM supports Windows NT 4.0, 32-bit/64-bit 2000/XP/2003/Vista/7 ...
  • Page 16: Specifications

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3.3 Specifications  System: 80186, 80MHz or compatible 512 KB SRAM Flash ROM: 512 KB; Erase unit is one sector (64 KB); 100,000 Flash Memory erase/write cycles Built-in Watchdog Timer Sys, Link/Act...
  • Page 17 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru  Interface: Models PDS-220FT PDS-220FC PDS-220FCS PDS-220FCS-60 100 Base-FX, 100 Base-FX, 100 Base-FX, 100 Base-FX, Fiber Port (ST connector) (SC connector) (SC connector) (SC connector) Multi-mode fiber cables: Single-mode fiber Single mode fiber 50/125, 62.5/125 or 100/140 μm...
  • Page 18 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru  Power: Power reverse polarity protection Protection +12 ~ +48 V (non-regulated) Input Range Power Consumption 0.14A @ 24 V Yes, for EMS Protection. Frame GND  Mechanism: Models PDS-220FT...
  • Page 19: Front View

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3.4 Front View  PDS-220FT Front View: External Power Supply LED Indicator 100 Base-FX Fiber Port (ST connector) Robust insulated COM1: RS-232 and fire retardant case COM2: RS-485 ...
  • Page 20: Pin Assignments

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3.5 Pin Assignments  Pin Assignments for PDS-220Fx Series models: PDS-220Fx Series User Manual (V1.2, Apr. 2015)
  • Page 21: Dimensions

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3.6 Dimensions  Dimensions for PDS-220Fx Series models: Left Side View Front View Top View Right Side View Back View Bottom View PDS-220Fx Series User Manual (V1.2, Apr. 2015)
  • Page 22: Setting Up The Pds-220Fx Module

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4. Setting up the PDS-220Fx Module Step 1: Connect the PDS-220Fx to the Ethernet Network Before connecting the PDS-220Fx module to a fiber optic network, the following items are needed: 1: Power Supply: 12 ~ 48 V (eg: DP-665)
  • Page 23 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru  Connect both the NS-200AFx module and your computer to the same sub network or the same Switch.  Short the RXD and TXD pins of the PDS- 220Fx module for execute a self-test.
  • Page 24 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step 2: Search for the PDS-220Fx on the Ethernet network 1. Execute the VxComm Utility and then search for your PDS-220Fx series module. 2. Double click the name of the PDS-220Fx to open the configuration settings dialog box. Click the “Search Severs”...
  • Page 25 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step 3: Configuring Virtual COM Ports 1. Click the “Search Servers” button again to search for your PDS-220Fx series module to make sure that the new IP/Mask/Gateway settings have been saved, then click the name of your PDS-220FX series module once to select it.
  • Page 26 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Check the Virtual COM port numbers on the PC. Check COM Port 4. Click “Restart Driver” from the “Tools” menu, and then click the “Restart Driver” button to start the driver.
  • Page 27 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step4: Testing your PDS-220Fx 1. Connect the “RxD” and the “TxD” of the COM2 on the PDS-220Fx module, as shown in the diagram in Step1. 2. Right click Port 1 and then choose the “Open COM Port” option. 3.
  • Page 28 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4. Type a string in the send field then click the “Send” button. If a response is received, it will be displayed in the received field. Click this button to send a string to your module The response is displayed Complete...
  • Page 29: Configuration With Web Browser

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5. Configuration with Web Browser Once the PDS-220Fx series module has been correctly configured and is networking normally, the configuration details can be retrieved or amended using either the VxComm Utility or a standard web browser, such as IE, FireFox, or Mozilla, etc.
  • Page 30: Network Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.2 Network Settings Network (TCP/IP) Setup page: IP Address Subnet Mask Gateway The above three items are the most important network settings and should always correspond to the LAN definition. If they do not match, the PDS-220Fx series module will not operate correctly.
  • Page 31 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru UDP Search: 0 = disabled, 1 = always enabled. 2 = enable the UDP Search function until another client is connected. (Default = 2) By keeping the UDP search setting as 2, the PDS-220Fx loading will be reduced. The VxComm Utility will not be able to search for this module until this module’s clients are all disconnected.
  • Page 32 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Network WDT timeout (ms): 0 = disabled, min. = 30000. If the PDS-220Fx series module does not receive any data from any of the clients within the period of the “Network WDT timeout”, the module will reboot itself. The default setting should be 300000ms (= 300 seconds).
  • Page 33: Ip Filter Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.3 IP filter Settings The IP filter setting limits which client PCs are able to link to the PDS-220FX series module via specific IP addresses. When one or more IP addresses are set in the filter table, only client PCs where the IP address is included in the range listed of the filter table will be able to connect to the PDS-220Fx series module.
  • Page 34 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Set IP1+Mask: Set the IP Filter (Available IP) range, the IP address must be entered in the “IP1” text field and Mask address must be entered in the “IP2/MASK” text field, as the image below shows.
  • Page 35: Com Port Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.4 COM Port Settings The COM Port Settings list is saved in the EEPROM on the PDS-220Fx series module. PDS-220Fx Series User Manual (V1.2, Apr. 2015)
  • Page 36 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru The Currently Used COM Port Settings list. The COM Port Settings area: Save current settings to EEPROM: If the “Set COM Port” button is clicked without checking “Save current settings to EEPROM”, option the new settings will be saved to the PDS-220Fx series only and the new settings will be valid after the next power-on.
  • Page 37 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Port: The COM Port number on the PDS-220Fx series module. Baud Rate, Data Bits, Parity Stops Bits, End Char: The configuration settings should match the serial device used. Rx FIFO Trigger Level: This option is used to set the number of characters that the COM Port can receive at once time, the PDS-220Fx will move the data from the COM Port FIFO to the PDS-220Fx.
  • Page 38 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Condition 2: No clients send any requests to the PDS-220Fx series module. The PDS- 220Fx series module echoes data from the devices to each connected client.  M1: Slave Mode (Single-echo mode) Condition 1: One client sends a request to the PDS-220Fx series module to access the...
  • Page 39 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru No clients send any requests to the PDS-220Fx series module. The PDS- Condition 2: 220Fx series module doesn’t echo any data from the devices to any client. ...
  • Page 40 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Slave Timeout (ms): In M1 mode, the slave mode timeout setting is use to set the waiting time after last character of the request sent to the device. If the device does not respond within the timeout value, the PDS-220Fx series module will return a timeout error and process next request.
  • Page 41: Modbus Gateway Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.5 Modbus Gateway Settings Check the Modbus Device ID of PDS-220Fx module: Check the COM Port for Modbus Gateway settings: PDS-220Fx Series User Manual (V1.2, Apr. 2015)
  • Page 42 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru The COM Port Settings area: Device ID: Sets the device ID of PDS-220Fx module. Port (COM0 for ALL Ports): Select the COM port by you used for PDS-220Fx module.
  • Page 43: Miscellaneous Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.6 Miscellaneous Settings Alias Name: allocates and alias to the PDS-220Fx series module. Web Read Only: 0 = disabled, 1 = enabled If the “Web Read Only” properly is set to 1, enabled, the web server will not be able to save any new configurations to the PDS-220Fx series module.
  • Page 44 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2. Set the new “Web Read Only” properly = 0 and click the “UPDATE” button. 3. Check that the current the “Web Read Only” = 0 and then click “Logout” to complete the operation.
  • Page 45: Pair Connection Settings

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 5.7 Pair Connection Settings For example: Item Model Name Server mode Configuration IP Address PDS-220Fx #1 PDS-220FT Client 10.0.8.5 PDS-220Fx #2 PDS-220FT Server 10.0.8.6 Contact your Network Administrator to obtain a correct and workable network configuration (such as IP/Mask/Gateway) for PDS-220Fx series modules.
  • Page 46 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru “COM Port Setting” Click the tag to enter the settings page, and select the “115200” “8, None, in Baud Rate field and 1” in data format field for example. Check the “Save current settings to EEPROM”...
  • Page 47 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru “Add COM” Select and type in the COM port of the PDS-220Fx #1 (Client) which you want to use. Type in the COM port, IP and cmd port (default: 10000) of the PDS-220Fx #2 “Save to EEPROM”...
  • Page 48: Modbus Testing And Protocol

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 6. Modbus Testing and Protocol Step1: Install Modbus Utility on your PC The software is located at: CD: \NAPDOS\Modbus\modubs_utility http://ftp.icpdas.com/pub/cd/8000cd/napdos/modbus/modbus_utility/ Step2: Connecting the Modbus device to PDS-220Fx 1.
  • Page 49: Modbus/Tcp To Modbus/Rtu Gateway

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 6.1 Modbus/TCP to Modbus/RTU Gateway PDS-220Fx series module can work as a Modbus/TCP to Modbus/RTU gateway that supports most SCADA/HMI communications based on the Modbus/TCP protocol. Step1: Configuring COM Ports for Modbus Gateway 1.
  • Page 50 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2. Enter the configuration of PDS-220Fx web server and then check your firmware version is v3.2.32[Jul 06 2012] or later, please also refer to Section 5.1 Connecting to the PDS-220Fx module.
  • Page 51 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step2: Test Modbus/TCP to Modbus/RTU Gateway 1. Run the Modbus Utility program and then click the “Modbus/TCP” button. Double Click Click 2. Click on “Client tools”  “Modbus/TCP Client”. Click PDS-220Fx Series User Manual (V1.2, Apr.
  • Page 52 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Enter the IP address of PDS-220Fx series module and then click “Connect” button to connect the PDS-220Fx series module. Type the IP address of PDS-220Fx 4. Refer to “Protocol Description” and type command in the command field then click the “Send Command”...
  • Page 53: Testing Modbus Device Through Virtual Com Ports

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 6.2 Testing Modbus Device through Virtual COM Ports If want to use Modbus/RTU through Virtual COM Ports, you can refer to below steps. Step1: Configuring COM Ports for Virtual COM 1.
  • Page 54 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 4. Add Server(s) in the VxComm Utility, please refer to Section 4 Setting up the PDS- 220Fx Module. 5. Run Modbus Utility program and click the “Modbus/TCP” button and then click on “Client tools”...
  • Page 55 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 6. Select your virtual COM port and baud rate (Default: 9600) on PDS-220Fx series module and then click the “Open” button. Select COM Port = COM3; Baud rate = 9600 7.
  • Page 56: Console / Telnet Commands List

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7. Console / Telnet Commands List 7.1 Operation Flowchart PDS-220Fx Power OFF SW1 is in “Run” SW1 is in “Init” position position Power ON Power ON Init Mode Run Mode *for MiniOS7 Commands *for Virtual COM applications...
  • Page 57: Regulate Init/Normal(Run) Mode

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7.2 Regulate Init/Normal(Run) Mode  Comparison Sheet (Init/Run Modes) VCOM Telnet Console Mode Firmware Commands Commands Commands Stop Init Init Mode is used to upgrade firmware and accepts MiniOS7 commands (from PDS.COM1) only.
  • Page 58: Command List

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Command List Sec. Command Description Retrieves/Sets the IP addresses that are allowed to access the PDS- 7.3.1 IPFILTER 220Fx. Queries the network configuration. (IP/Mask/Gateway/MAC 7.3.2 IPCONF addresses). Lists all the status of sockets (Listen/Not Used Yet) together with the 7.3.3 SOCKET...
  • Page 59: Ipfilter

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru IPFILTER 7.3.1 Description: This command is used to query or edit IP filter table. The IP filter table restricts the access of packets based on the IP header. If one or more IP addresses are saved into the IP filter table, only clients whose IP is specified in the IP filter table can access the PDS-220Fx.
  • Page 60: Ipconf

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Example: IPCONF 7.3.2 Description: This command is used to display the network configuration information, such as IP/Mask/Gateway/MAC addresses and the status of DHCP/ACK_Delay/Free Memory/Socket status. Effect: Immediate Command Argument Description...
  • Page 61: Socket

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru SOCKET 7.3.3 Description: This command lists the status of all sockets (Listen/Not Used Yet) together with the type of each socket (TCP Server: Port No./UDP/Unused) If stat = 1, the socket is used. If stat = 0, the socket is not yet used. Take Effect: Immediately Command Argument...
  • Page 62: Com

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7.3.4 Description: This command queries or sets the configuration of the COM Ports (Baud Rate/Parity/Stop bits). Effect: Immediate Command Arguments Description Queries the configuration of all COM Ports. Queries configuration of COM Port “n”.
  • Page 63: Broadcast

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Broadcast 7.3.5 Description: This command is used to Enable/Disable listening broadcast packets on PDS-220Fx. Effect: Immediate Command Arguments Description Broadcast Queries the Broadcast settings. Sets Broadcast = 1. Broadcast The system is able to receive broadcast packets.
  • Page 64: Sockettimeout (Ms)

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru SocketTimeout (ms) 7.3.7 Description: This command is used to query or set the SocketTimeout parameter. If the SocketTimeout is greater than zero, and the PDS-220Fx does not receive any data from a client PC for longer than the SocketTimeout period, the PDS-220Fx will close the socket connection between itself and the client PC.
  • Page 65: Echocmdno

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru EchoCmdNo 7.3.9 Description: This command is used to query or set the EchoCmdNo parameter. The EchoCmdNo parameter is used to set whether the PDS-220Fx prefixes the Virtual COM command to the corresponding response.
  • Page 66: Endchar

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru EndChar 7.3.10 Description: This command is used to query or set the EndChar parameter. PDS-220Fx sends out the response string from serial port to TCP client immediately when it received a char on the response string that matching the EndChar.
  • Page 67: Mask

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7.3.11 Description: This command is used to query or set the IP address. Effect: After the next reboot. Command Arguments Description Queries the IP address. = xxx.xxx.xxx.xxx Sets the IP address.
  • Page 68: Gateway

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru GATEWAY 7.3.13 Description: This command is used to query or set the outgoing Gateway address of the subnet. Effect: After the next reboot. Command Arguments Description Gateway Queries the Gateway address.
  • Page 69: Name

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru NAME 7.3.15 Description: This command is used to query the name of a PDS-220Fx module. Effect: Setting the name is not allowed. Command Arguments Description name Queries the name of a PDS-220Fx module. Example: ALIAS 7.3.16...
  • Page 70: Dhcp

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru DHCP 7.3.17 Description: This command is used to set the DHCP client to either enabled or disabled. DHCP function will get a dynamic IP address setting for PDS-220Fx automatically. Thus it's recommended to disable DHCP function and use a static IP address setting.
  • Page 71: Ver

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 7.3.19 Description: This command is used to query the version information for a PDS-220Fx module. Effect: Setting the version information is not allowed. Command Argument Description Queries the version information. Example: SAVE 7.3.20...
  • Page 72: Load

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru LOAD 7.3.21 Description: This command is used to loads file to the built-in flash disk on PDS-220Fx module. It should be used to update firmware only. Effect: Immediate Command Argument Description...
  • Page 73 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru [21-2] Save=1 Load vc6_3230.exe ※ When save = 1, system will back up the "autoexec.bat" and "vcom.ini" files to memory first, clear all files in the flash disk, and then load the "autoexec.bat" and "vcom.ini" files from memory and run the “load”...
  • Page 74: Config

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru CONFIG 7.3.22 Description: This command is used to clear the settings in the EEPROM. Effect: Immediate Command Argument Description Clears the settings in the EEPROM. config = RESET After reboot, the firmware will use the new (default) settings on EEPROM.
  • Page 75: Reset

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru RESET 7.3.23 Description: This command is used to reboot the PDS-220Fx module. Effect: Immediate Command Argument Description reset Reboot the PDS-220Fx series module. Example: QUIT 7.3.24 Description: This command is used to stop and quit the firmware of PDS-220Fx series module.
  • Page 76: Appendix A: Linking To A Development Pc

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Appendix A: Linking to a Development PC Step 1: Connect the download-cable, CA0910, between the PDS-220Fx series module and COM 1 (or COM 2) of the development PC as per below the diagram. Step 2: Switch the SW1 in the Init mode position.
  • Page 77 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step 5: Execute 7188XW.EXE/C#, and change the Baud Rate to 115200 bps, N81. “/C#” is the COM Port of the development PC. Step 6: Press [Enter] twice on the development PC: Step 7: Read the configuration of the PDS-220Fx: Read configuration command ...
  • Page 78 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru “setcom” parameters are as follows: 1 - 8 Port 2 - 921600 Baud 7, 8 DataBit N, n : None parity Parity E, e : Even parity O, o : Odd parity M, m : Mark, parity = 1 S, s : Space, parity = 0...
  • Page 79 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Step 10: Execute ping 192.168.255.1 –t using a run command as follows: Execute Ping 192.168.255.1 on the PC client. The ping results should be smooth and continuous Note: ...
  • Page 80: Appendix B: Frame Ground

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Appendix B: Frame Ground Electronic circuits are constantly vulnerable to Electro Static Discharge (ESD), which becomes worse in a continental climate area. PDS-220Fx series modules feature a new design for the frame ground, which provides a path for bypassing ESD, allowing enhanced static protection (ESD) capability and ensures that the module is more reliable.
  • Page 81: Glossary

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Glossary 1. ARP (Address Resolution Protocol) Consider two machines A and B that share a physical network. Each has an assigned IP address IP and IP , and a MAC address the MAC and MAC .
  • Page 82: Ethernet

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 3. Ethernet The term Ethernet generally refers to a standard published in 1982 by Digital Equipment Corp., Intel Corp. and Xerox Corp. Ethernet is the most popular physical layer local area network (LAN) technology today.
  • Page 83: Mac (Media Access Control) Address

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 9. MAC (Media Access Control) address To allow a computer to determine which packets are meant for it, each computer attached to an Ethernet is assigned a 48-bit integer known as its MAC address (also called an Ethernet address, hardware address or physical address).
  • Page 84: Subnet Mask

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 14. Subnet Mask Subnet mask is often simply called the mask. Given its own IP address and its subnet mask, a host can determine if a TCP/IP packet is destined for a host that is (1) on its own subnet, or (2) on a different network.
  • Page 85: Faq

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 1. How to access the remote PDS-220Fx that placed behind an NAT or firewall? The remote site must have a NAT (or a router supports NAT) server. NAT stands for Network Address Translator.
  • Page 86: How To Open A Virtual Com Port That Larger Than "Com 9" By Calling Createfile() Win32 Api

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 2. How to open a virtual COM port that larger than "COM 9" by calling CreateFile() Win32 API? If you want to open "COM 10", the correct way to call the CreateFile() is as follows: CreateFile( "\\\\.
  • Page 87: Doesv X Comm Driver (Pc) Support Auto - Reconnection After Fixing A Network Break

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Does VxComm Driver (PC) support auto-reconnection after fixing a network break? Yes, the VxComm Driver (PC) supports the auto-reconnection mechanism in version 2.00 and above. The VxComm Utility allows the user to set the Keep-Alive Time (ms) and Connection-Broken Time (ms) in the server options.
  • Page 88: Does The Transmission Speed Become Faster When The Serial Device Working With Serial To Ethernet Device Servers

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Does the transmission speed become faster when the serial device working with Serial to Ethernet device servers? The speed depends on the applications. For transparent applications, it includes Ethernet latency in transmission and may get slower.
  • Page 89 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru For Xserver applications, it can become faster. User can write their own Xserver applications to acquire data automatically, and then compress and transmit this large amount data at one time. Your application can reach high performance by pre-acquire data before asking by client and then response immediately.
  • Page 90: Public ) Internet Connection

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 6. Why does the PDS-220Fx series module fail on a (public) Internet connection? The default IP address of the PDS-220Fx series module is 192.168.255.1, which can be only used on a private Internet connection.
  • Page 91 ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru A private internet client may communicate with a public Internet server (PDS-220Fx series module) only if the NAT service for the client is available. Note: Internet Assigned Numbers Authority IANA Request for Comments Internet Service Providers...
  • Page 92: Device

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru How many PCs can be connected to a single PDS-220Fx device? This depends on how many serial ports are available on the PDS-220Fx series module and how many serial ports which can be connected to each PC of PDS-220Fx. The PDS-220Fx series module has 32 sockets in total includes some reserved listening sockets.
  • Page 93: Can I Use The Setcommstate ( ) Api To Changes The Baud Rate/Data Format Settings Of A Virtual Com Port

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru Can I use the SetCommState ( ) API to changes the Baud Rate/data format settings of a virtual COM port? Yes. In a Win32 environment, the CreateFile( ) API should be called to open the COM Port(s) and then the SetCommState( ) API can be used to configure the settings.
  • Page 94: Series Module

    ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ +7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 10. Why cannot computer ping or search the PDS-220Fx series module? The computer can make a communication with the module through some specific ports. Please confirm with your network administrator that UDP Port 7, Port 23, Port 57188 and Port 54321 can’t be denying by network device.

This manual is also suitable for:

Pds-220ftPds-220fcPds-220fcsPds-220fcs-60

Table of Contents