Holding Current Reduction - Festo VAEM-V-S8EPRS2 Operating Instructions Manual

Valve control module
Hide thumbs Also See for VAEM-V-S8EPRS2:
Table of Contents

Advertisement

Product overview
Fig. 1 Valve parameter description
Legend
Valve parameters
1
T_Delay
2
T_Inrush
3
T_Tau
4
T_On
5
T_Switch_Off
6
I_Inrush
7
I_Hold
Tab. 2
5.1.2

Holding current reduction

Function description
The integrated holding current reduction reduces the current consumption to the set holding current
after the adjustable pickup time has elapsed.
With holding current reduction, the output current of the valve is measured and the signal at the VAEM
output is adjusted and controlled in accordance with the set parameters.
Reduction of the heat development of the solenoid valve coil
Increased service life of solenoid valves
Lower power consumption
Improvement of the switching times of solenoid valves
6
Description
Delay time
Pickup time
Current reduction time
Switching time
Cooldown
Parameters cannot be set individually
T_Switch_Off is a constant 4 ms
Inrush current
Holding current
Festo — VAEM-V-S8EPRS2 — 2020-07