Air Inlet Housing Replacement - Lycoming TEO-540-C1A Maintenance Manual

Table of Contents

Advertisement

B. Induction Housing Installation
(1) Install the induction housing on the oil sump.
(2) Install and torque the four bolts and 10 bolts with new lock washers in the induction
housing per the Standard Torque Tables in the latest revision of the Service Table of
Limits - SSP-1776.

5. Air Inlet Housing Replacement

A. Air Inlet Housing Removal
(1) Remove the six bolts and washers from the air inlet housing (Figure 2).
(2) Remove the air inlet housing and gasket from the induction housing. Discard the gasket.
B. Air Inlet Housing Installation
(1) Install the air inlet housing (Figure 2) with a new gasket on the induction housing with
the six bolts and washers.
(2) Torque the bolts to 96 to 106 in.-lb. (11 to 12 Nm).