Lycoming TEO-540-C1A Maintenance Manual page 53

Table of Contents

Advertisement

TEO-540-C1A Engine Maintenance Manual
TEO-540-C1A Engine Maintenance Manual
50-Hour Engine Inspection Checklist for TEO-540-C1A Engines (Cont.)
Inspection Item
Fuel System
Complete the "Fuel System
Inspection" and checklist in
Chapter 73-10.
Induction System
Complete the Induction
System Inspection.
Engine Cylinders
Examine the rocker box covers for
oil leaks. Identify and correct the
cause of oil leaks (Chapter 72-30).
For possible causes and corrections,
refer to the section "Fault Isolation
Guide" in Chapter 12-30.
Alternator
Make sure the alternator belt
support bracket and mountings
are tight.
Exhaust System
Examine the exhaust system.
Operational Test
Complete the Operational
Ground Check in Chapter 72-
00.
© 2018 Avco Corporation. All Rights Reserved
November 2018
Comments
Refer to the "Induction
System Inspection"
procedure in Chapter 72-80.
Cyl. 1
Cyl. 2
Tighten all loose hardware
per torque values in the
Standard Torque Tables in
the latest revision of the
Service Table of Limits -
SSP-1776.
Complete the section "50-
Hour Exhaust System
Inspection" in Chapter 78-
00.
Results/Notes
Cyl. 3
Cyl. 4
Cyl. 5
Done
Cyl. 6
05-20
Page 23