Visual Inspection Checklist for TEO-540-C1A Engines (Cont.)
Item
Engine Controls
Examine all engine controls for
general condition, full travel, and
freedom of operation in accordance
with the aircraft manufacturer's
instructions
Look for any illuminated NTO,
TLO, or FFL lights.
Follow-Up Action:
(4) Make sure any items removed during inspection, in the engine compartment, are securely
in place and not loose. Remove any foreign object debris (FOD) from the engine
compartment.
(5) Start the engine and run-up per instructions in the "Engine Initiation" chapter of the TEO-
540-C1A Engine Installation and Operation Manual.
(6) Operate the engine for 3 minutes on the ground (per the TEO-540-C1A Engine
Installation and Operation Manual.) Complete a leak check while the engine is in
operation.
(7) Shut down the engine and proceed with the routine inspection or engine service.
(8) Copy and complete the Operational Leak Check Sheet for TEO-540-C1A engines on the
next page.
(9) Identify and correct all leaks. Record all leaks and corrective action on the Operational
Leak Check Sheet for TEO-540-C1A Engines.
(10) Re-install the engine cowling per the aircraft manufacturer's instructions.
© 2018 Avco Corporation. All Rights Reserved